Point-of-Care Testing, Activated Clotting Time (ACT) Synonyms ACT; Activated Clotting Time; POCT, Activated Clotting Time

Test Includes Activated clotting time only

Laboratory Point-of-Care Testing

Request Form Provider's Order

Phone (212) 305-9291

Availability Operating hours at Point-of-Care

Turnaround Time <5 minutes

Specimen Blood (arterial, venous), freshly drawn

Minimum Volume 2.5 mL

Container 3 mL syringe

Storage Instructions Test immediately.

Causes for Rejection Clotted specimen

Reference Range Reference ranges are specific for exact testing procedure, which is defined at each POC that preforms ACT.

Critical Values Provider defined

Use Monitoring of patients under treatment with heparin


Copyright © 1978-2002 Lexi-Comp Inc. All Rights Reserved