Aluminum, Plasma
Synonyms
Al, Blood
Laboratory
Core Laboratory
Referral to
Reference Laboratory
Request Form
Routine Blood Requisition
Phone
(212) 305-8600
Availability
Daily, 24 hours
Turnaround Time
4-6 days
Special Instructions
Specimen should be drawn at least 24 hours after the dose of any aluminum containing antacid. Obtain a royal blue top Vacutainer® (for trace metals) from the laboratory
Specimen
Blood
Volume
7 mL
Minimum Volume
3 mL
Container
Royal blue top tube; obtain from the laboratory.
Collection
Blood samples should be obtained with stainless steel needle and plastic syringe, or collected in a special metal-free navy blue top tube.
Storage Instructions
Centrifuge, transfer to plastic tube, and refrigerate.
Causes for Rejection
Use of nonacid-washed collection tube, hemodialysis
Reference Range
3-10
g/L; dialysis patients: <40
g/L
Use
Evaluate dialysis encephalopathy, osteomalacic dialysis osteodystrophy in patients on hemodialysis; evaluate toxicity
Methodology
Atomic absorption (AA)